{"id":4785,"date":"2022-08-19T12:49:10","date_gmt":"2022-08-19T12:49:10","guid":{"rendered":"https:\/\/tridelta-meidensha.de\/?page_id=4785"},"modified":"2025-08-28T13:12:36","modified_gmt":"2025-08-28T13:12:36","slug":"monitoramento","status":"publish","type":"page","link":"https:\/\/tridelta-meidensha.de\/pt-pt\/produtos\/monitoramento\/","title":{"rendered":"Monitoramento"},"content":{"rendered":"<div class=\"hero-blue\">\n    <div class=\"hero-blue__text\">\n        <p class=\"hero-blue__text__subheadline\">Monitoring solutions<\/p>\n        <h1 class=\"hero-blue__text__headline\"><\/h1>\n        <p class=\"hero-blue__text__description\">Product details<\/p>\n                <div class=\"main-btn\">\n            <a href=\"https:\/\/tridelta-meidensha.de\/en\/contact\/\" target=\"_blank\">Contact us!<\/a>\n        <\/div>\n        \n\n    <\/div>\n    <div class=\"hero-blue__background\">\n                    <img decoding=\"async\" src=\"https:\/\/tridelta-meidensha.de\/wp-content\/uploads\/2022\/08\/AdobeStock_225606429-scaled.jpeg\" height=\"\" width=\"\" alt=\"\"\/>\n            <\/div>\n<\/div>\n\n    <section class=\"single-paragraph single-paragraph--background\">\n        <p>With our meters of the DCC series, with or without leakage current measurement, and our control spark gaps, impending faults can also be detected at an early stage before they lead to an impairment of the security of supply.<\/p>\n<p>Due to the ever advancing digitalization, we have launched a new arrester monitoring device in 2020. The smartCOUNT is an intelligent device for monitoring the condition of the arrester. For this purpose, it automatically measures both leakage current and pulse currents and generates trend curves from them, which can be displayed via a website. From these trend curves, forecasts are possible, which are helpful in monitoring the condition of the arresters. This enables you to detect and replace age-weak devices in good time before a protection failure is imminent.<\/p>\n    <\/section>\n\n\n<section class=\"serviceSlider-intro\">\n    <div class=\"serviceSlider-intro__container\">\n        <div class=\"serviceSlider-intro__text\">\n            <h3>Portfolio<\/h3>\n            <p>With our products, we offer competitive and cost-effective ways to monitor surge arresters and detect problems in time. <\/p>\n        <\/div>\n    <\/div>\n<\/section>\n\n<section class=\"swiper-cards-blueBackground swiper-cards-blueBackground--negativeMargin\">\n    <div class=\"swiper swiper-blueBackground\">\n        <div class=\"swiper-wrapper\">\n\n                                    <div class=\"swiper-slide image-card\">\n                            <label for=\"checkboxtoggle-0\" class=\"toggle\">\n                                <p class=\"slide-title\">Surge counter DCC 2 &#038; DCC-ML 2<\/p>\n                                <div class=\"image-container\">\n                                                                            <img decoding=\"async\" src=\"https:\/\/tridelta-meidensha.de\/wp-content\/uploads\/2022\/08\/Zaehler-1.png\" height=\"\" width=\"\" alt=\"\"\/>\n                                                                    <\/div>\n                            <\/label>\n                        <\/div>\n                                                            <div class=\"swiper-slide image-card\">\n                            <label for=\"checkboxtoggle-1\" class=\"toggle\">\n                                <p class=\"slide-title\">smartCOUNT<\/p>\n                                <div class=\"image-container\">\n                                                                            <img decoding=\"async\" src=\"https:\/\/tridelta-meidensha.de\/wp-content\/uploads\/2022\/08\/AdobeStock_225606429-scaled.jpeg\" height=\"\" width=\"\" alt=\"\"\/>\n                                                                    <\/div>\n                            <\/label>\n                        <\/div>\n                                                            <div class=\"swiper-slide image-card\">\n                            <label for=\"checkboxtoggle-2\" class=\"toggle\">\n                                <p class=\"slide-title\">Monitoring spark gap<\/p>\n                                <div class=\"image-container\">\n                                                                            <img decoding=\"async\" src=\"https:\/\/tridelta-meidensha.de\/wp-content\/uploads\/2023\/01\/KoFu-1.png\" height=\"\" width=\"\" alt=\"\"\/>\n                                                                    <\/div>\n                            <\/label>\n                        <\/div>\n                                            <\/div>\n        <div class=\"swiper-button-prev\"><\/div>\n        <div class=\"swiper-button-next\"><\/div>\n    <\/div>\n\n    <input type=\"checkbox\" id=\"checkboxtoggle-0\" class=\"inputtogle\"\/><div class=\"slide-extraContent\">\n                                        <div class=\"slide-extraContent__header\">\n                                            <div class=\"text\">\n                                                <h2 class=\"title\">Technical Data<\/h2>\n                                                <p class=\"description\">Counter: 6-digit display<br \/>\r\nMinimum sensitivity of the counting current: 100 A (8\/20 \u00b5s)<br \/>\r\nHigh impulse current resistance: 100 kA (4\/10 \u00b5s)<br \/>\r\nVoltage drop at 20 kA (8\/20 \u00b5s): 1 kVs<br \/>\r\nMeasuring scale DCC &#8211; ML2: 0 to 50 mA irms<br \/>\r\nMaximum counting speed: 5 counts per second<\/p>\n                                                 <div class=\"description\"><\/div>\n                                            <\/div><div class=\"picture\">\n                                                    <img decoding=\"async\" src=\"https:\/\/tridelta-meidensha.de\/wp-content\/uploads\/2022\/08\/Zaehler-1.png\" height=\"\" width=\"\" alt=\"\" title=\"Z\u00e4hler\"\/>\n                                                    <p style=\"font-size:12px;   margin-top:-20px; margin-left:10px\">Z\u00e4hler<\/p>\n                                                <\/div>   <\/div> <div class=\"slide-extraContent__threeColumns\"><div class=\"column\">\n                                                                    <p class=\"title mheight2\"><\/p>\n                                                                    <p class=\"description\"><\/p>\n                                                                <\/div> <\/div> <div class=\"slide-extraContent__twoColumns\">\n                                            <h2 class=\"title\"><\/h2>\n                                            <div class=\"columns\">\n                                                <div class=\"column\">  <p class=\"description\">Our pulse counters are suitable for arrester types of different manufacturers. The devices do not require an auxiliary voltage supply and are designed for use in the earth line of an arrester.  Optionally, the pulse counter type DCC 2 can also be connected in the common earth line of three arresters. <\/p>       <\/div>\n                                                <div class=\"column\">  <p class=\"description\">The pulse counter can be mounted by means of M12 gland on the rear lug or with additional bracket by means of screws 2x M12x25. The DCC2 and DCC-ML2 pulse counters are equipped with functionally safe electrical circuits and require no maintenance other than cleaning the viewing window and the feedthrough. <\/p>       <\/div>\n                                            <\/div>\n                                        <\/div><\/div><input type=\"checkbox\" id=\"checkboxtoggle-1\" class=\"inputtogle\"\/><div class=\"slide-extraContent\">\n                                        <div class=\"slide-extraContent__header\">\n                                            <div class=\"text\">\n                                                <h2 class=\"title\">Do it the smart way.<\/h2>\n                                                <p class=\"description\"><\/p>\n                                                 <div class=\"description\"><p><a href=\"https:\/\/www.smartcount.info\" target=\"_blank\" rel=\"noopener\">https:\/\/www.smartcount.info<\/a><\/p>\n<\/div>\n                                            <\/div><div class=\"picture\">\n                                                    <img decoding=\"async\" src=\"https:\/\/tridelta-meidensha.de\/wp-content\/uploads\/2022\/08\/overview-1-scaled.jpg\" height=\"\" width=\"\" alt=\"\" title=\"overview\"\/>\n                                                    <p style=\"font-size:12px;   margin-top:-20px; margin-left:10px\">overview<\/p>\n                                                <\/div>   <\/div> <div class=\"slide-extraContent__threeColumns\"><div class=\"column\">\n                                                                    <p class=\"title mheight2\"><\/p>\n                                                                    <p class=\"description\"><\/p>\n                                                                <\/div> <\/div> <div class=\"slide-extraContent__twoColumns\">\n                                            <h2 class=\"title\"><\/h2>\n                                            <div class=\"columns\">\n                                                <div class=\"column\">  <p class=\"description\">smartCOUNT reduces planned and unplanned shutdowns by detecting faulty arresters and providing reliable information about their condition. It can be installed on any gapless ZnO surge arrester, thus improving the reliability of your new and existing substations. Tridelta Meidensha&#8217;s international team listens to the specific needs and requirements of all customers around the world and developed another breakthrough solution for trustworthy safety. smartCOUNT is the first of a new generation of condition monitoring devices that can detect and even distinguish typical faults in time.  <\/p>       <\/div>\n                                                <div class=\"column\">  <p class=\"description\">Simply install the smartCOUNT app on your NFC-enabled Android phone, read the automatically collected data and know what&#8217;s going on &#8211; before it&#8217;s too late. You&#8217;ll be alerted to leakage current anomalies; dirty enclosures, moisture intrusion or metal oxide aging can be easily detected and distinguished. In short, smartCOUNT monitors the condition of your surge arrester and detects typical arrester failure symptoms &#8211; simply and clearly. And it is much cheaper than the worst case. <\/p>       <\/div>\n                                            <\/div>\n                                        <\/div><\/div><input type=\"checkbox\" id=\"checkboxtoggle-2\" class=\"inputtogle\"\/><div class=\"slide-extraContent\">\n                                        <div class=\"slide-extraContent__header\">\n                                            <div class=\"text\">\n                                                <h2 class=\"title\"><\/h2>\n                                                <p class=\"description\"><\/p>\n                                                 <div class=\"description\"><\/div>\n                                            <\/div><div class=\"picture\">\n                                                    <img decoding=\"async\" src=\"https:\/\/tridelta-meidensha.de\/wp-content\/uploads\/2023\/01\/KoFu-1.png\" height=\"\" width=\"\" alt=\"\" title=\"Monitoring spark gap\"\/>\n                                                    <p style=\"font-size:12px;   margin-top:-20px; margin-left:10px\">Monitoring spark gap<\/p>\n                                                <\/div>   <\/div> <div class=\"slide-extraContent__threeColumns\"><div class=\"column\">\n                                                                    <p class=\"title mheight2\"><\/p>\n                                                                    <p class=\"description\"><\/p>\n                                                                <\/div> <\/div> <div class=\"slide-extraContent__twoColumns\">\n                                            <h2 class=\"title\"><\/h2>\n                                            <div class=\"columns\">\n                                                <div class=\"column\">  <p class=\"description\">Control spark gaps are connected in the ground line of the surge arrester. The surge arrester must be insulated. Characteristic markings on the electrodes of the control spark gap become visible as a result of the discharge processes caused by lightning or switching overvoltages. These markings allow a qualitative and quantitative analysis of the discharge processes through the arrester.<\/p>       <\/div>\n                                                <div class=\"column\">  <p class=\"description\">Attention: Checking the control spark gap is only permissible when the system is in the enabled state.<\/p>       <\/div>\n                                            <\/div>\n                                        <\/div><\/div>\n\n\n\n<\/section>\n\n<section class=\"banner nannertop\">\n        <div class=\"banner__text\">\n        <h1 class=\"banner__text__headline\">Contact us now!<\/h1>\n        <p class=\"banner__text__description\">We will be happy to advise you &#8211; by phone or e-mail. <\/p>\n        <div class=\"banner__text__buttons\">\n                            <div class=\"main-btn main-btn--blue-envelope\">\n                    <a href=\"mailto:arrester@tridelta-meidensha.de\" target=\"_blank\">Write an e-mail<\/a>\n                <\/div>\n                                        <div class=\"main-btn main-btn--yellow-phone\">\n                    <a href=\"tel:+49366019328300\" target=\"\">Or call us: +49 (0) 36601 9328 300<\/a>\n                <\/div>\n                    <\/div>\n    <\/div>\n    <div class=\"banner__background\">\n                    <img decoding=\"async\" src=\"https:\/\/tridelta-meidensha.de\/wp-content\/uploads\/2022\/08\/tridelta-meidensha_DSC09748-scaled.jpg\" height=\"\" width=\"\" alt=\"\"\/>\n            <\/div>\n<\/section>","protected":false},"excerpt":{"rendered":"","protected":false},"author":2,"featured_media":0,"parent":4770,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"inline_featured_image":false,"footnotes":""},"class_list":["post-4785","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/tridelta-meidensha.de\/pt-pt\/wp-json\/wp\/v2\/pages\/4785","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/tridelta-meidensha.de\/pt-pt\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/tridelta-meidensha.de\/pt-pt\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/tridelta-meidensha.de\/pt-pt\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/tridelta-meidensha.de\/pt-pt\/wp-json\/wp\/v2\/comments?post=4785"}],"version-history":[{"count":2,"href":"https:\/\/tridelta-meidensha.de\/pt-pt\/wp-json\/wp\/v2\/pages\/4785\/revisions"}],"predecessor-version":[{"id":4804,"href":"https:\/\/tridelta-meidensha.de\/pt-pt\/wp-json\/wp\/v2\/pages\/4785\/revisions\/4804"}],"up":[{"embeddable":true,"href":"https:\/\/tridelta-meidensha.de\/pt-pt\/wp-json\/wp\/v2\/pages\/4770"}],"wp:attachment":[{"href":"https:\/\/tridelta-meidensha.de\/pt-pt\/wp-json\/wp\/v2\/media?parent=4785"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}